4.1.11 Selecting a printer
Press
"SELECT" Display Meaning/function
11 x The following settings are possible:
11
11
1 = external printer 20 characters (Switzerland)
22
22
2 = internal printer (PDR 078)
33
33
3 = external printer (PDR 200)
4.1.12 Selecting the operator terminal
Press
"SELECT" Display Meaning/function
12 x The following settings are possible:
11
11
1 = Pocket keypad PT 14 (V24 interface)
22
22
2 = Data terminal DTL 224 (RS 232 interface)
4.1.13 Temperature compensation
Press
"SELECT" Display Meaning/function
13 x If "
nono
nono
no" appears in the display window for engine speed, the
temperature-compensation sequence has not been enabled.
To enable temperature compensation, this function must be
selected as described in Section 4.4.
Before temperature compensation, please observe the follo-
wing points:
- Let device cool for 2 hours with cover closed.
- Set up switched-off device in a calm spot free from
draughts.
- Switch on device with cover closed.
An automatic sequence takes place. The current ADC values
are shown in the display window for HC, CO and CO
2
. After
approx. 100 minutes, "
i.0.i.0.
i.0.i.0.
i.0." appears in the engine-speed dis-
play window once compensation has been successfully com
pleted.
tE.Ei
no tc.An
7.345 7.446
7.407
i.0 tc.Ei
L P.Ei