FLEXIDOME corner 7100i IR Installation | en 11
Bosch Security Systems
Installation Manual
2023-10 | 01 |
I/O Connector
1 3 5 7
2 4 6
8
7 mm
[0.28”]
Pin Connection
1 ALARM OUT
2 ALARM OUT
3 ALARM IN
4 GND
5 AUDIO IN
6 GND
7 GND
8 AUDIO OUT
Grounding
The camera does not require a safety earth connection, but grounding is recommended for
outdoor applications.
Grounding provides improved surge protection (up to 1kV, 1 kA to ground (8/20 µs pulse)).
The grounding wire is not included in the box. Bosch recommends the use of a grounding
wire with a ring terminal.
The ring terminal must not have a thickness greater than 2mm (0.01in.).
i
Notice!
Use proper surge protection on cables that are routed outdoors, or close to large inductive
loads or electrical mains supply cables.