EasyManuals Logo

Bosch GLM 50 C User Manual

Bosch GLM 50 C
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
-37-
Error Message
If a measurement is not done correctly, the error mes-
sage “Error” appears in the display Turn the laser
measure o and on again, and start the measurement
again.
The symbol to the left will appear if there is a
defect with the laser measure. If this is the
case, have the laser measure checked by an
after sales service agent for Bosch power
tools.
Maintenance and Service
Keep the laser measure clean at
all times.
Do not immerse the laser measure into water or other
fluids.
Wipe o debris using a moist and soft cloth. Do not
use any cleaning agents or solvents.
Maintain the reception lens 14 in particular, with the
same care as required for eye glasses or the lens of a
camera.
If the laser measure should fail despite the care tak-
en in manufacturing and testing procedures, repair
should be carried out by an authorized after-sales ser-
vice center for Bosch power tools. Do not open the
laser measure yourself.
In all correspondence and spare parts orders, please
always include the 10-digit article number given on the
type plate of the laser measure.
ENVIRONMENT PROTECTION
Recycle raw materials & batteries instead
of disposing of waste. The unit, accesso-
ries, packaging & used batteries should
be sorted for environmentally friendly
recycling in accordance with the latest
regulations.

Other manuals for Bosch GLM 50 C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch GLM 50 C and is the answer not in the manual?

Bosch GLM 50 C Specifications

General IconGeneral
Accuracy±1.5 mm
Bluetooth ConnectivityYes
Laser Diode635 nm, <1 mW
Laser Class2
Memory30 measurements
Storage Temperature-20°C to +70°C
Protection ClassIP54
Measuring Range0.05 m to 50 m
DisplayColor display with backlight
Power Source2 x 1.5 V LR03 (AAA) batteries
Weight0.1 kg
Automatic Deactivation5 minutes
Units of Measurementm/cm, ft/in
Battery LifeApprox. 10, 000 measurements
Operating Temperature-10°C to +45°C