20/68 Transport and storage
Bosch Rexroth Mellansel AB, Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
Fig. 11: Filling the motor with oil
6.2.2 Storing for extended periods or in uncontrolled environment
NOTICE
Insucient cleanliness!
Risk of damage to equipment.
▶ Take extreme care to ensure that no contamination enters the motor.
If the motor is stored for more than 3 months in uncontrolled environment or more
than 12 months in controlled environment, it must be totally lled with oil according
to below:
1 Place the motor as shown in Fig. 10, B) Standing with shaft vertical.
2 Fill the motor full with ltered oil containing a mixture of 2% Shell VSI 8235, or
similar compatible corrosion inhibitor in the selected uid in the following order:
D1, A1, C1.
NOTE! See Table 6 for oil volume.
3 Fit the plug to D1.
4 Seal connections A1 and C1 with the cover plates tted to the connection surface
at delivery. Check that the O-rings or rubber seals are in position in the cover
plates
5 Position the motor as shown in Fig. 10, A) Standing with shaft horizontal or alt.
B) Standing with shaft vertical.
6 The motor must be turned a few revolutions once a month to prevent internal
corrosion in the motor.
A1 C1 D1
DD00100068
Motor size Motor case oil volume including channels
Litre US gallon
CB 280 15 4.0
CB 400 21 5.5
CB 560 19 5.0
CB 800 25 6.6
CB 1120 32 8.5
Table 6: Motor case oil volume
Cover plate