EasyManua.ls Logo

Bosch IDS BOVB60-20 - Page 21

Bosch IDS BOVB60-20
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
| 21
Installation Instructions
Bosch IDS BOVB20 Split System Heat Pump - BTC 761701316 C (02.2022)
Figure 32
Wiring for 1H and 1C thermostat
Y2
C
Y
C G
THERMOSTAT
INDOOR UNIT
OUTDOOR UNIT
G
R
O/B
H/DH
W2
W1
C
Y
B
W
B
Dh
Y1
R
GRAY
PURPLE
BROWN
BLUE
GREEN
RED
YELLOW
BROWN
YELLOW
BLUE
Note: Because Y1 and Y2 are
jumped, the indoor fan will only run
in high stage.
Thermostat Wiring Diagram for BOVB20/BVA20 Matched System
Figure 33
Wiring for 2H and 1C thermostat
Y2
C
Y
C
G
THERMOSTAT
INDOOR UNIT
OUTDOOR UNIT
G
R
O/B
H/DH
W2
W1
C
Y
B
W
B
Dh
Y1
R
GRAY
PURPLE
BROWN
BLUE
GREEN
RED
YELLOW
BROWN
YELLOW
BLUE
W/E
WHITE/BLACK
WHITE
WHITE
Note: Because Y1 and Y2 are
jumped, the indoor fan will only run
in high stage.
Note: W1 and W2 are jumped, so
Electric Heat will only function in
high stage.
Thermostat Wiring Diagram for BOVB20/BVA20 Matched System

Table of Contents

Related product manuals