84 en | Appendices MAP 5000
2018.08 | 23 | F.01U.168.332 Installation manual Bosch Sicherheitssysteme GmbH
May view device status X X X
May view duress alarm X X X
May view alarm count X X X
May view event memory X X X
May view control panel history X X
May print control panel history X X
May view control panel version X X X
Maintenance category permissions 1 2A 2B 3 4
May adjust control center volume/brightness X X
May change output state X X
May set date time X
May test bell X X
May test motion detectors X X X
May walk test automatic points X
May walk test points X
Tab.8.6: SES Permissions
See also
Installer button, page 66
Manufacturer authorization, page 59
8.3.5 Tamper surveillance of the main panel
Tamper switch with wall tamper
4 When mounting the enclosure and installing the tamper switch, take the wall tamper of
the panel into account (refer to Mounting the enclosure, page 17 and Installing and
connecting the tamper switch, page 51).
Location supervision of the panel
External alarm signaling by means of siren and/or remote alarm signaling with communicator
must be planned in accordance with Sirens and communicator in accordance with EN50131
grade 3, page 62.
1. In case of variants A, B and C with communicator(s) of classes 3 and 4, provide location
supervision for the panel as soon as one or more areas are armed.
It is possible to omit location supervision for variant D with class 5 communicator.
2. Realize the location supervision as a technical solution by the intrusion alarm system
itself. Therefore, ensure the EN-compliance of the requirements for disarming.
Or:
Realize the location supervision by security-relevant persons who guarantee that actions
that pose a risk to security are detected at all times at the time of the required location
supervision.