Loading...
Rexroth Diax 04 HDD and HDS Ratings and Dimensions 3-3
DOK-DIAX04-HDD+HDS*UL*-IB01-EN-P
3.2 HDS03.2 … HDS05.2
Description Symbol Unit
HDS03.2-
W075N
HDS03.2-
W100N
HDS04.2-
W200N
HDS05.2-
W300N
listing according UL-standard (UL) UL 508 C
listing according CSA-standard (UL) Canadian National Standard(s) C22.2 No. 14-05
UL files (UL) E 134201
pollution degree (UL) Use in a pollution degree 2 environment
maximum ambient temperature with
nominal data (UL)
T
amax
°C 45
maximum ambient temperature with
reduced nominal data (UL)
T
amax_red
°C 55
Weight mkg11111925
device height (UL)
1)
H mm 498
device depth (UL)
2)
T mm 308
device width (UL)
3)
B mm 100 100 150 200
minimum distance on the top of the
device
4)
d
top
mm 300
minimum distance on the bottom of the
device
5)
d
bot
mm 100
rated control voltage input (UL)
6)
U
N3
V 26 ±2%
rated power consumption control
voltage input without holding brake,
without control section at
U
N3
= DC 24 V (UL)
P
N3
W25253055
short circuit current rating, SCCR,
symmetrical amperes (UL)
7)
I
SCCR
A rms 42000
rated input voltage, power (UL)
8)
V 530 … 670
maximum input current (UL)
9)
I
L_cont
A376060140
field wiring material (UL)
10)
Use 60/75 °C copper wire only, use class 1 wire only or
equivalent
maximum output voltage (UL) U
out
V 500
output number of phases (UL) 3
maximum output current (UL) I
out_max
A 40 50 120 175
maximum output frequency (UL) f
out
Hz 1000
power dissipation at continuous current
I
out_cont
and continuous DC bus power
P
DC_cont
respectively (UL)
11)
P
Diss_cont
W 220 280 800 1200
1) 2) 3)
housing dimension; see related dimension sheet also
4) 5)
see fig. "Air intake and air outlet of drive controller"
6)
observe supply voltage for motor holding brakes
7)
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with
listed AC input line fuses or listed circuit breakers specified in this
documentation.
8)
HDS, HDD, HZB, HZK: DC bus L+, L-; HVE/HVR: mains input U, V, W
9)
at P
DC_cont
10)
find value for tightening torque in project planning manual, electrical
terminals
11)
plus dissipation of braking resistor
Abb. 3-3: UL ratings and dimensions