5-10 Instructions for Use Rexroth Diax 04 HDD and HDS
DOK-DIAX04-HDD+HDS*UL*-IB01-EN-P
Fig. 5-17: Horizontally arranged mounting plate
X6, Holding brake, motor temperature monitoring
Technical data of connector
Ap5332f1.FH7
123456 7
Fig. 5-18: Connector X6
Type No. of pins Design
screw-type terminal 7 pins at the unit
Fig. 5-19: Design
Cross section
single wire
[mm²]
Cross section
multi core wire
[mm²]
Cross section
in AWG
gauge no.
0,14 - 1,5 0,14 - 1,5 28 - 16
Fig. 5-20: Connection cross section
AP5154F1.FH7
1
2
4
5
E
H
AC Motor
M
3
A1 A2 A3
A
B
C
D
X6
holding
brake
F
G
3
6
TM+
TM-
BR+
BR-
U
B
0V
B
24V
Ext
0V
Ext
24V
PTC /
NTC
(depends on motor type)
U
HDS
7
XS1
shield for motor
cable
Fig. 5-21: Motor cable, holding brake and temperature monitor connection
Illustration
Design
Connection cross section
Connector X6,holding brake, for
temperature monitor