Assembly 31/52
RE24751-XE-B/10.19, H-4WEH...XE..., BoschRexrothAG
Fig. 4: Cable and line entry
1 O-ring
2 Double nipple
3 Seal insert
4 Screw-in bushing
5 Clamping screws of the strain relief
In the state as delivered, the cable and line entry is already screwed in the
terminal box of the valve.
1. De-energize and depressurize the relevant system part.
2. Open the terminal box (internal hexagon, wrench size3)
3. Remove the outer sheath of the connection line and the insulation of the
individual conductors. Press the wire end ferrules to the individual conductors.
For the stripping lengths, refer to fig.5 and table10.
1
2
3
4
5