Loading...
Damage to the device!
NOTICE
Provide strain relief for the terminal connectors of the device in the control
cabinet or use the optionally available connection accessory HAS02.
HCS02.1E-W0012, -W0028
View Identifica‐
tion
Function 3-phase operation Function 1-phase operation
L1 Connection to supply mains (L1)
L2 Connection to supply mains
(L2)
Connection to neutral con‐
ductor supply mains
L3 Connection to supply mains
(L3)
n.c.
Connection of equipment grounding conductor of drive con‐
troller
Screw connection at connector Unit Min. Max.
Tightening torque Nm 0,5 0,6
Connection cross section
Stranded wire
mm
2
1,5 4
AWG 16 10
Occurring current load and minimum required
connection cross section
See technical data of device used (I
LN
and A
LN
)
Occurring voltage load See technical data of device used (U
LN
)
Fig.5-4: Function, Pin Assignment, Properties
HCS02.1E-W0054, -W0070
View Identifica‐
tion
Function 3‑phase operation Function 1‑phase operation
(only HCS02.1E)
L1 Connection to supply mains (L1)
L2 Connection to supply mains
(L2)
Connection to neutral con‐
ductor supply mains
L3 Connection to supply mains
(L3)
n.c.
Connection of equipment grounding conductor of drive con‐
troller
Screw connection at connector Unit Min. Max.
Tightening torque Nm 1,5 1,7
Connection cross section
Stranded wire
mm
2
1,5 16
AWG 16 6
Bosch Rexroth AG DOK-INDRV*-HCS02******-IT01-EN-P