Connection cable
Stranded wire
mm
2
1,0 4
AWG 18 10
Occurring current load and minimum required
connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Short circuit protection A1, A2, A3 against each other and each of them against
ground
Fig.5-6: Function, Pin Assignment, Properties
HCS02.1E-W0054, -W0070
View Identifica‐
tion
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
For equipment grounding conductor of motor
Screw connection at connector Unit Min. Max.
Tightening torque Nm 1,5 1,7
Connection cable
Stranded wire
mm
2
1,5 16
AWG 16 6
Occurring current load and minimum required
connection cross section
A See Technical Data of device used (I
out
)
Occurring voltage load V See Technical Data of device used (U
out
)
Short circuit protection A1, A2, A3 against each other and each of them against
ground
Fig.5-7: Function, Pin Assignment, Properties
5.2.5 X6, Motor Temperature Monitoring and Motor Holding Brake
Lethal electric shock by live parts with more
than 50 V!
WARNING
Exclusively operate the device
with plugged on connectors (even if there haven't been any lines con‐
nected to the connectors) and
with connected equipment grounding conductor!
Bosch Rexroth AG DOK-INDRV*-HCS02******-IT01-EN-P
Rexroth IndraDrive Drive Controllers Power Sections HCS02
34/67
Instructions for Use

Table of Contents