2 Ratings and dimensions
2.1 HCS02
UL ratings and dimensions
Description Symbol Unit
HCS02.1E-
W0012-_-03
HCS02.1E-
W0028-_-03
HCS02.1E-
W0054-_-03
HCS02.1E-
W0070-_-03
Listing in accordance with UL
standard
UL 508C
Listing in accordance with CSA
standard
C22.2 No. 274-13
UL files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Ambient temperature range with
reduced nominal data
T
amax_red
°C 55
Mass m kg 2.90 3.80 6.70 6.80
Device height
1)
H mm 290 352
Device depth
2)
T mm 206
Device width
3)
B mm 65 105
Minimum distance on the top of
the device
4)
d
top
mm 80
Minimum distance on the bottom
of the device
5)
d
bot
mm 80
Horizontal spacing at the device
6)
d
hor
mm 5
Rated control voltage input
7)
U
N3
V 24 ± 20%
Rated power consumption control
voltage input at U
N3
8)
P
N3
W 12 14 23
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
9)
U
LN_nom
V 3 x AC 200...500
Tolerance rated input voltage U
LN
% ± 10
Mains frequency
f
LN
Hz 50...60
Tolerance input frequency Hz ± 2
Rated input current
I
LN
A 6.0 13.0 20.0 30.0
Branch circuit protection fuse
10)
20 25 40
Required wire size in accordance
with NFPA 79 and UL 508 A
(internal wiring);
11)
A
LN
AWG 14 AWG 12 AWG 10 AWG
Latest amendment: 2019-02-20
IndraDrive Drive Controllers Power Sections HCS02 5/21
Ratings and dimensions
R911319657_Edition 09 Bosch Rexroth AG