View Connection Signal name Function
PE Equipment grounding conductor
14 L- Power supply, DC 750 V, 25 A
13 L+
12 0V 42 V supply, max. 15 A
11 42V
10 Ext_SI_Ch1_In (X103.1)
Ext_SI_Ch1 (X103.2)
Control signals (24 V)
9 Ext_GND_In (X103.1)
Ext_GND (X103.2)
8 Ext_SI_Ch2_In (X103.1)
Ext_SI_Ch2 (X103.2)
7 bModulbus
6 bE_Stop_In (X103.1)
bE_Stop_Out (X103.2)
5 Shield Multi-Ethernet
4 RxD-
3 TxD-
2 TxD+
1 RxD+
Contact design Pins at device
Tab. 6-21: Function, pin assignment, properties
Notes on installation
Exclusively operate KSM02/KMS02/KMS03 at a KCU02 or KMV03.
Always connect the hybrid cable of KCU02 to the connection point
X103.1 of the first KSM02/KMS02 of a drive line.
Hybrid cables contain power lines and control lines. Always route hybrid
cables in such a way that the hybrid cables are protected against
external damage (in accordance with EN 61800‑5‑1 and EN 61800‑5‑2).
Notes on operation
Do not remove connectors when the component has been powered. Do
not plug in connectors when the component has been powered.
Avoid removing and plugging in the hybrid cable unless it is necessary.
Allowed number of plugging cycles: ≤ 50
164/407
Connection points
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Bosch Rexroth AG R911335703_Edition 04