14.2 Digital outputs
14.2.1 Digital outputs (safety technology L options)
The digital outputs are compatible with digital inputs of types 1, 2 and 3
(IEC 61131).
Fig. 14-3: Symbol
Data Unit Min. Max.
Supply voltage (U
ext
) V 19,2 30
Current consumption (I
ext
) mA 700
Output voltage ON V 18,2 30
Output voltage OFF V 5
Output current ON mA 350
Allowed energy content of
connected inductive loads, e.g.
relay coils; only allowed as
single pulse
mJ 400
Short circuit protection Available
Overload protection Available
Tab. 14-5: Digital outputs (safety technology L options)