22/36 Commissioning
Bosch Rexroth AG, Valve amplifier VT-MSPA, RE 30232-B/08.2020
8.3.2 Test jacks
I
B
Actual current in solenoid B (VT-MSPA2-2X), I with VT-MSPA1-2X
I
A
Actual current in solenoid A (VT-MSPA2-2X)
Reference potential
v Internal command value or set value
8.4 Selecting the valve types
When setting a valve, the operator generally must ensure that no command value and
no enable is applied to the VT-MSPAx-2X!
The desired valve type has to be selected by means of the two rotary switches, see
Fig. 4 item 4. The left-hand rotary switch sets the tens place, the right-hand rotary
switch the units place of the item. While you make the settings, test jack “v“ outputs
the selected rotary switch position as a voltage value in 100-mV increments.
The following valve types are available.
VT-MSPA1-2X
Standard Expert
Rotary switch
position
Valve type
(one solenoid)
t Z G 4Q t1 t2 t3 t4 GB GA SB SA B f Inv DIn
0-0 No valid valve -
0-1 4WRA6...-2X
0-2 4WRA10...-2X
0-3 4WRZ...-7X
0-4 3DREP6...-2X
0-5 4WRPH6...-2X (SO855)
0-6 DBEP6...-1X
0-7 DBET-6X...G24...
0-8 DBET-6X...G24-8...
0-9 DBETX-1X...G24-25...
1-0 DBETX-1X...G24-8...
1-1 (Z)DBE6-2X...
1-2 DBEM10...-7X...G24...
1-3 DBEM10...-7X...G24-8...
1-4 DBEM20...-7X...G24...
1-5 DBEM20...-7X...G24-8...
1-6 DBEM30...-7X...G24...
Indicator lamps Operational state Display mode Meaning
LED DI “digital input“
(yellow)
Normal operation Permanently ON/OFF Status of digital input
Setup Flashing Standard setup active
Setup OFF Expert setup active
Setup ON/blinking/flickering Expert setup: Setting of enable input
LED “ready” (red/
green)
Normal operation Permanently on green Module ready for operation
Normal operation Permanently on red Error
Normal operation and setup Blinking red/green Valve number changed (but not confirmed)
Normal operation and setup Blinking red Invalid valve number
Normal operation OFF Module not ready for operation
Setup Flashing green Expert setup active

Table of Contents