Commissioning 29/36
RE 30232-B/08.2020, Valve amplifier VT-MSPA, Bosch Rexroth AG
Parameter LED
indicator
lamps
Description Editable
parameter
Output at test jack v
Biasing current B (solenoid
A + B)
t
Z/B
G
S
DI
B
A
v
v
Biasing current
of solenoid A and
solenoid B
0...step height %:
0...5.0 V
PWM frequency, relative, f
Universal valves: absolute
t
Z/B
G
S
DI
PWM
t
PWM frequency,
relative
Universal valves,
absolute
80 % to 120 % of the nominal
frequency
0.8 V...1.2 V
0.95 V...5.05 V (100 Hz/V)
95 Hz ... 505 Hz
Command value inversion
Inv
t
G
S
Z/B
DI
Command value inversion ON/OFF ON: +1 V
OFF: 0 V
Function:
Digital (enable) input DI
t
Z/B
G
S
DI
Digital (enable) input 1: Enable input
(default)
2: Inversion
2) 3)
3: Ramp ON/
OFF
3)
4: Changeover
simple ramp/4Q
ramp
3)
1: 1 V
2: 2 V
3: 3 V
4: 4 V
1) Ramp times effective only when 4Q operating mode is activated
2) Function available only on VT-MSPA2-2X/..
3) The function of the digital input is XOR-linked to the internally selected state
8.7 Restoring the VT-MSPA...-2X to factory settings
This function is available exclusively directly upon switching on the operating
voltage. It resets all customer-specific parameters of the set valve to the factory
settings.
The module has to be de-energized.
1. Press and hold [Set] and switch on the supply voltage.
The LEDs signal the status shown on the left.
1. After some time, the LEDs switch to the status shown on the left.
The module is restored to factory settings.
2. Release [Set].
Restoring to factory settings is completed.