24/36 Commissioning
Bosch Rexroth AG, Valve amplifier VT-MSPA, RE 30232-B/08.2020
VT-MSPA2-2X
Standard Expert
Rotary switch
position
Valve type
(two solenoids)
t Z G 4Q t1 t2 t3 t4 GB GA SB SA B f Inv DIn
0-0 no valve – – – – – – – – – – – – – – –
0-1 4WRA6...-2X
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-2 4WRA10...-2X
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-3 4WRZ...-7X
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-4 3DREP6...-2X
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-5 3DREP6...-2X (SO674)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-6 DBEP6...-1X
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
0-7 ... 3-6 – – – – – – – – – – – – – – – – –
3-7 Pump control 1 (0.74 A)
EP (A4CSG)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
3-8 --- 3-9 ‒ – – – – – – – – – – – – – – – –
9-6 Universal (0.8 A)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
9-7 Universal (1.6 A)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
9-8 Universal (2.5 A)
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
If no valve type is selected, the LEDs signal the status shown on the left. The yellow
LEDs rotate clockwise in pairs.
The “ready” LED blinks
red/green, if the valve number saved last and the
current rotary switch position do not match!
The amplifier is active and utilizes the parameters of the valve type saved last.
Remedy:
If you wish to change the valve, remove the command value and the enable, press
key [Set] > 1 sec and accept the new valve type.
If the rotary switch position was changed accidentally, reset it to the original
valve number.
→ The “ready” LED
is lit green.
In both cases, check the actually connected valve!
Whenever a valve is changed, all changeable parameters are reset to factory
settings!
t
Z/B
G
S
DI