1 689 989 458 2020-01-01
|
Robert Bosch GmbH
20 | VDI III | Cleaning and maintenance Decommissioning | VDI III | 21en
6.11 Computer application is unable
to communicate with VDI III by
WLAN or Ethernet
1. Make sure the WLAN USB adapter is securely
attached to VDI III.
2. Make sure VDI III can make a connection by
USB.
3. If using point-to-point, make sure the compu-
ter has no more than one dongle connected
to it:
$ Connect VDI III to the computer by USB.
$ In VCI Manager, make sure the connection
is enabled and the IP configuration is
correct.
4. If using the workshop's WLAN network:
Contact the IT department and make sure the
computer is detecting the access point and the
security settings for VDI III have been configu
-
red correctly.
7. Cleaning and mainte-
nance
The housing of VDI III may only be cleaned with a
soft cloth and a neutral cleaning agent. Do not use
abrasive cleaning agents or coarse workshop rags.
i VDI III does not contain any parts that can be
maintained by the user. Do not open VDI III.
Opening it will void the warranty.
¶ Do not immerse VDI III or any of its parts or
accessories in water.
¶ Even though VDI III and its accessories are
water-resistant, they are not waterproof. Allow to
dry completely before storing.
¶ Avoid using harsh solvents such as petrole-
um-based cleaning agents, acetone, benzene,
trichloroethylene etc.
7.1 Restoring the VDI III system soft-
ware (recovery)
As a result of a power failure or a connection error
during a software update, the VDI III software may
become corrupted. In this case, it is necessary to
perform a recovery:
1. Connect VDI III to the computer by USB connec-
ting cable.
2. Launch VCI Manager.
3. Select VDI III in "VCI Explorer."
4. To start the recovery, press and hold the power
button on
VDI III
for at least 5seconds.
The VDI III icon in VCI Manager is marked "Re
-
covery."
5. Select VDI III in VCI Manager.
6. Carry out recovery.
7.2 Spare and wearing parts
Kit component Part number
VCI system tester 1 699 200 873
Diagnostic connection cable
(data transmission to J1962)
1)
1 699 200 366
USB connecting cable A to B, 3m
1)
F00K.108.653
WLAN USB stick
1)
1 687 010 590
Test adapter (self-test)
1) 2)
1 699 200 154
1) Wearing part
2) Special accessory