EasyManua.ls Logo

Bosch Therm 4300 Series - Using the Water Heater; Pre-Startup Checks

Bosch Therm 4300 Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Use
Therm 4300 – 6 720 821 607 (2018/01)
3Use
Open all water and gas blocking devices.
Purge the pipes.
CAUTION: The area in front of the burner
can reach very high temperatures, and there
is a risk of burning on contact.
3.1 Digital display - description
Fig. 3 Digital display
[1] Temperature/error code
[2] Malfunction indicator
[3] Temperature measurement units
[4] Heater in operation (burner turned on)
3.2 Before starting up the heater
CAUTION:
The initial startup of the heater must be
realized by a qualified technician, who
will provide the client with all the
information necessary for its correct
usage.
Check if the gas indicated on the type plate is the same as
the on
e used at the location.
Open the gas valve.
Open the water valve.
3.3 Turning the heater on and off
Turning on
Press the switch
, position .
Fig. 4
Green light on = Main burner on
Fig. 5
Turning off
Press the switch
, position .
3.4 Water flow
If the red LED starts flashing, check the water pressure.
Fig. 6