7
Technical Characteristics and Dimensions
Therm 4300 – 6 720 821 607 (2018/01)
2.6 Dimensions
Fig. 1
[4] Heat exchanger
[5] Burner
[10] Temperature/volume selector
[20] Gas connection
[23] Ignition unit
[26] Power selector
[34] LED - Burner status check
[35] Switch / LED - Low water flow indicator
[36] Front cover
[37] Hole for fixing to wall
[38] Exhaust pipe union
[39] Flue with non-return device
[40] Gas valve
[42] Digital display
Table 3 Dimensions
Dimensions (mm) A B C D E F G H (Ø)
Natural gas LPG
T4300 11-2D... 310 580 228 112,5 463 60 25
1/2”
T4300 14-2D... 350 655 228 125 510 95 30 1/2”
T4300 18-2D... 425 655 334 125 540 65 30 1/2”