15
Adjustments (must be carried out only by qualified technicians)
Therm 4300 – 6 720 821 607 (2018/01)
6.2 Pressure regulation
Access to the adjuster screw
▶ Remove the appliance front cover ( see sec
tion 5.3).
Connection of manometer
▶ Loosen the shutter screw.
▶ Connect the manometer to the burner pressure measuring
po
int.
Fig. 12 Pressure measurement point
Maximum gas flow adjustment
▶ Remove the seal from the adjusting screw (Fig. 13).
▶ Turn on the heater with the power selector set to the left
(maximum positi
on).
Fig. 13 Maximum gas flow adjusting screw
▶ Open several hot water taps.
▶ Using the adjusting screw (Fig. 13), regulate the pressure
until achieving the values indicated in the table 7.
▶ Seal the adjusting screw once again.
Minimum gas flow adjustment
The minimum gas flow adjustment is
performed automatically after the
adjustment of the maximum gas flow.
Table 7 Burner pressure
Natural
gas H
Butane Propane
Injector code 11 8708202113
(110
)
8 708 202 130
(70)
8708202124
(120)
8708202128
(72)
14 8 708 202 113
(110
)
8708202128
(72)
8708202116
(125)
8708202132
(75)
18 8708202115
(115
)
8708202130
(70)
8708202116
(125)
8708202132
(75)
Connection
pressu
re (kPa)
11
14
18
2,0 2,8
3,7
Burner pressure
MAX (kPa)
11 1,27 2,8 3,5
14 1,2 2,8
3,5
18 1,03 2,55 3,25
6.3 Conversion to a different type of gas
Only use the original conversion kits.
The conversion must only be per
formed by a qualified
technician. The original conversion kits are supplied with
assembly instructions.