Loading...
Installation (only for approved contractors)
Tronic 5000 – 6721830067 (2021/06)
14
Loosen and remove the front fascia of the appliance.
Fig. 11
Turn around the hot water pipe.
Open the side fixing parts of the hydraulic block.
Fig. 12
Remove the hydraulic block from the back.
Fig. 13
5.4 Water connection
NOTICE
Damages to the installation!
Damages to the water pipework.
Ensure that the pipework can withstand a maximum
pressure of 10 bar and a maximum temperature of 100 °C.
NOTICE
Danger of damage to the appliance!
The existence of sand can cause a reduction in the flow rate and
its obstruction in more serious cases.
Purge the water circuit before installing the appliance.
Accessories
The accessories supplied with the device must be used, as
shown in Fig. 15.
Only use taps and accessories with capacity to operate in a
closed circuit (under pressure).

Table of Contents