Installation (only for approved contractors)
Tronic 5000 – 6721830067 (2021/06)
18
The spacers should be placed at the back of the appliance.
Fig. 25
[1] Spacers
Level the appliance with the upper mounting fixing and the
spacers, if the distance between the appliance and the wall
is 8-16 mm.
Fig. 26
If the appliance is not securely fixed to the wall,
Use the screws to fix the spacers to the wall.
Fig. 27
After levelling the appliance,
Tighten the fixings so that the appliance is secured to the
wall.
Fig. 28
5.7 Hydraulic block assembly
Position the hydraulic block into the back of the appliance.