- 6 721 846 263 (2022/01)6
3 Appliance information
3.1 General information
Standard package:
A - Floor standing oil fired condensing boiler
B - Literature pack:
• Greenstar Danesmoor Installation, Commissioning and Servicing
instruction manual
• User Instructions
• Fascia information card
• Guarantee registration card
C - BSP plug, one inch (Regular only)
D - ErP label
E - Flue damper
3.2 Technical data
6720821720 - 05.1Wo
D
600mm
370mm
855mm
B
C
A
E
Description Units 12/18 18/25 25/32
Central heating
Central heat output (max) kW 18 25 32
Primary water capacity (total) litres 20 21 22
Maximum static head metres 30 30 30
Minimum static head metres 111
Water side resistance (20°C
difference)
mbar 20 30 56
Maximum available pump head
(20°C difference) Utility System
mH
2
O 5.2 4.3 4.1
Maximum permissible sealed
system operating pressure in
accordance with WRAS
guidelines
bar 2.5 2.5 2.5
Flue
Exit flue gas mass flow kg/hr 29 40 51
Pipework connections
Fuel line (compression) mm 10 10 10
Flow Utility BSP 1” 1” 1”
Flow Utility System mm 22 22 28
Utility flow and optional vent/air
vent
BSP 111
Return mm 22 22 28
Condensate (Polypropylene) mm 21.5 21.5 21.5
PRV outlet - Utility System mm 15 15 15
Electrical
Electrical power supply voltage ac ..V 230 230 230
Frequency Hz 50 50 50
Thermostats
Boiler flow temperature range °C 55/81 55/81 55/81
Control thermostat differential °C 555
Boiler high limit thermostat set
point
°C 95 95 95
Boiler manual reset overheat
thermostat set point
°C 105 105 105
Flue manual reset overheat
thermostat set point
°C 110 110 110
General data
Maximum hearth temperature °C <100 <100 <100
SEDBUK 2009 % 90.7 90.6 90.5
SEDBUK 2005 % 93.0 92.9 92.7
Appliance protection rating IP 20 20 20
Weight (excluding packaging)
Utility Regular
kg 104 108 115
Weight (excluding packaging)
Utility System
kg 112 112 122