3.3 Energy efficiency
The following product data satisfy the requirements of the EU Regulations No. 811/2013 and No. 812/2013 supplementing Directive 2010/30/EU.
Product data Symbol Unit 7731600245 7731600246 7731600247 7731600254 7731600255 7731600256
Product type Danesmoor
Utility
Regular
2022+
12/18
Danesmoor
Utility
Regular
2022+
18/25
Danesmoor
Utility
Regular
2022+
25/32
Danesmoor
Utility
System
2022+
12/18
Danesmoor
Utility
System
2022+
18/25
Danesmoor
Utility
System
2022+
25/32
Condensing boiler Yes Yes Yes Yes Yes Yes
Low temperature boiler No No No No No No
B1 boiler No No No No No No
Cogeneration space heater
(CHP)
No No No No No No
Combination heater No No No No No No
Rated heat output P
rated
kW 18 25 32 18 25 32
Seasonal space heating
energy efficiency
s
% 929292929292
Energy efficiency class–AAAAAA
Useful heat output
At rated heat output and
high temperature regime
1)
1) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
P
4
kW 18.2 25.1 32.9 18.2 25.1 32.9
At 30 % of rated heat output
and low temperature regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW 5.6 7.8 10.0 5.6 7.8 10.0
Useful efficiency
At rated heat output and
high temperature regime
1)
4
% 91.8 91.9 91.5 91.8 91.9 91.5
At 30 % of rated heat output
and low temperature regime
2)
1
% 98.5 97.8 97.3 98.5 97.8 97.3
Auxiliary electricity consumption
At full load el
max
kW 0.165 0.159 0.150 0.165 0.159 0.150
At part load el
min
kW 0.053 0.049 0.047 0.053 0.049 0.047
In standby mode P
SB
kW000000
Other items
Standby heat loss P
stby
kW 0.166 0.159 0.161 0.166 0.159 0.161
Ignition burner power
consumption
P
ign
kW------
Emissions of nitrogen
oxides
NOx mg/kWh 110 103 109 110 103 109
Annual energy consumption Q
HE
GJ 57 78 103 57 78 103
Sound power level, indoors L
WA
dB(A)575654555655
Table 2 Product data for energy consumption

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch WORCESTER Danesmoor Utility Regular 2022+ 12/18 and is the answer not in the manual?

Bosch WORCESTER Danesmoor Utility Regular 2022+ 12/18 Specifications

General IconGeneral
BrandBosch
ModelWORCESTER Danesmoor Utility Regular 2022+ 12/18
CategoryBoiler
LanguageEnglish

Related product manuals