19
Menu 10: Load mode(mode 1)
LCD screen
number
Load mode Description
24h
000
0h
Normal
on mode
Manual mode
Pure light
control, turn on
the load at night
and turn off the
load during the
day
The load is always on.
When there is no sunlight, the
solar panel voltage is less than
the light control on voltage, the
controller delays for 1 minute
and then turns on the load ;
When there is sunlight, the solar
panel voltage is higher than the
light control off voltage,the
controller delays for 1 minute
and then turns off the load ;
00h
Pure light control
turns on the load
during the day
and turns off the
load at night
When there is no sunlight, the
solar panel voltage is less than
the light control on voltage, the
controller delays for 1 minute
and then turns off the load ;
When there is sunlight, the solar
panel voltage is higher than the
light control off voltage,the
controller delays for 1 minute
and then turns on the load
On the main menu interface,
press and hold [ENTER] for more
than 2s to turn on/off the load.
(not affected by light control)
16 9
81
Setting method: Same as above.