21
on: open load short-circuit protection
default
oFF: close load short-circuit
protection
Setting method: Same as above.
Menu 12: Load short circuit protectionmode 1)
16 9
81
Adjust current range: 0——rated current
for examplethe 60A controller
adjusting current range is 0-60A
Set 0No charging
Set 1——rated currentLimit charging
current1 step
Default: rated current
Setting method: Same as above.
Menu 13: Charging current (mode 1, mode 2)
16 9
81
oFF: The controller can not output
without battery. (default)
on: The controller can output without
battery.
Note: When the lead-acid battery cannot
work due to over-discharge, this function
can be turned on, and the controller can
activate the lead-acid battery with
constant voltage output lead acid battery
activation.
Setting method: Same as above.
Menu 14: Constant voltage output of lead acid battery
(mode 1, mode 2)
16 9
81