20
Note:① Make sure to connect the temperature sensor when turn on
the lithium battery low temperature charging protection.
②This menu will only appear when the battery type is set to LI or USE.
Setting method: Same as above.
LCD screen
number
Load
mode
Description
display: 11,
setting is
usually 1-14h
display: 22,
setting is
usually
01-014h
Pure light
control,turn on
the load at night
and turn off the
load during the
day + time
control
Pure light control
turns on the load
during the day
and turns off the
load at night +
time control
When there is no sunlight, the
solar panel voltage is less than
the light control on voltage, the
controller delays for 1 minute
and then turns off the load ;
When there is sunlight, the solar
panel voltage is higher than the
light control off voltage,the
controller delays for 1 minute
and then turns on the load.
When there is no sunlight, the
solar panel voltage is less than
the light control on voltage, the
controller delays for 1 minute
and then turns on the load ;
When there is sunlight, the solar
panel voltage is higher than the
light control off voltage,the
controller delays for 1 minute
and then turns off the load;
Menu 10.1: Light control mode + Duration mode(mode 1)
Menu 11: Lithium battery low temperature
charging protection (mode 1, mode 2)
The adjustment range is 1-14 hours.
①When menu 10 selects 11: 1-14h, 1 step
(default 1h)
②When menu 10 selects 22: 01-014h, 1
step (default 1h)
Setting method: Same as above.
①oFF: Turn off protection (default)
②on: Turn on the protection (the
temperature sensor detects that the
temperature is ≤0°C(32°F), start the
low temperature charging protection,
and do not charge the lithium battery
until the battery temperature returns to
2°C(35.6°F).
16 9
81
16 9
81