15 Fejlfinding USA.fm • Page 37Bale press
The baler cannot start and the start button
is flashing:
One flash, the door switch is reporting errors.
Two flashes, the emergency stop is activated.
Three flashes, the oil temperature is too high.
Four flashes, the motor temperature is too
high.
Five flashes, servicing is recommended.
Six flashes, other serious errors.
The filling door must be opened between
each press cycle.
Open and close the door completely.
Release the emergency stop.
Wait for the temperature to be normalized,
which can take a couple hours. (If the
problem is recurring, call for service).
Wait for the temperature to be normalized,
which can take a couple hours. (If the
problem is recurring, call for service).
Order a service from the dealer.
Contact the dealer.
The baler is very noisy:
Have one or more of the platen’s wear blocks
worn away?
Is the platen’s release roller worn?
Is a foreign object trapped between the
platen and the chamber?
Replace the wear blocks.
Replace the release roller.
Remove the foreign object.