CHAPTER 2 ENGINE3015R(h)/3515R(h)/4015R(h)/F36R(h)/F42R(h) TRACTOR
2
4.4.5 PC RS232 COMMUNICATION (LOW SPEED DATA DOWNLOAD AND REPROGRAM)
INTRODUCTION
A circuit connecting to scanner, which helps check a condition of DPF and repair.
1) Using 4 pins connecter between RS232 connecter and Data logger connector
2) 4pin connector (RS232_RX, RS232_TX, RS232_GND, USB1_CONNECT)
3) Logger reprogram : Connect RS232-to-USB Interface module to PC and start to download HEX le when
turn IG_KEY ON while running reprogram execution le provided
4) USB1_CONNECT : Signal to detect connecting RS232-to-USB I/F module from external
5) Data Download from Logger : Select downloading times to setting key among 2 second/10 secod/ 60
second because it needs about 19 hours to download at a speed of 115200BR (115200,8,N,1)
WIRING
910111213141516
12345678
SCAN -TOOL SIDE CONN
OBDII connector
PC
(
Notebook
)
RS 232
USB
A 2
A 1
B 1
A 4
Rx (TTL )
Tx (TTL )
USB 5V
RS 232 -to -USB
IF module
Rx ( TTL )
Tx ( TTL )
USB sensing
11
12
3
13
Logger
K25W247A