Gebrauchsanweisung/Technische Beschreibung
ACCULAN-Reamer GA 613
Instructions for use/Technical description
ACCULAN reamer GA 613
Mode d’emploi/Description technique
Moteur de fraisage/alésage ACCULAN GA 613
Instrucciones de manejo/Descripción técnica
Escariador ACCULAN GA 613
Istruzioni per l’uso/Descrizione tecnica
Alesatore ACCULAN GA 613
Instruções de utilização/Descrição técnica
Escareador ACCULAN GA 613
Gebruiksaanwijzing/Technische beschrijving
ACCULAN ruimer GA 613
Bruksanvisning/Teknisk beskrivning
ACCULAN märgborr GA 613

Table of Contents

Other manuals for Braun Aesculap Acculan

Questions and Answers

  • K
    Kathleen FisherAug 5, 2025
    What to do if the motor of my Braun Medical Equipment does not run?
    • S
      Samuel ThorntonAug 5, 2025
      If the motor of your Braun Medical Equipment does not run, it might be due to an oxidation film on the motor/battery connectors if the ACCULAN reamer is used infrequently. Try turning the drive shaft briefly by hand. Alternatively, the gear or bearing may be defective, requiring repair by the manufacturer.
  • D
    Dorothy JimenezAug 14, 2025
    Why is the motor of my Braun Aesculap Acculan Medical Equipment running too slowly?
    • B
      Barbara MillerAug 14, 2025
      If the motor of your Braun Medical Equipment runs too slowly or has too low a torque, the NiCd battery may be too weak or defective. Try changing the battery or checking the charger, and replace the battery if necessary.
  • T
    torresrebeccaAug 26, 2025
    What to do if Braun Medical Equipment motor runs but the tool does not turn?
    • H
      haasmichaelAug 27, 2025
      If the motor of your Braun Medical Equipment runs but the tool doesn't turn, the gear changer may not be snapped in at the end position. Ensure the gear changer is snapped in at the end position.

Summary

Product Overview

Explanation of Symbols

Device Purpose

Operational Modes

Initial Operation Setup

Component Installation

Inserting the Battery

Procedure for inserting the battery into the reamer, referencing Figures 1-3.

Removing the Battery

Procedure for removing the battery from the reamer, referencing Figure 4.

Operation with Cement Injector

Instructions for operating the reamer with the Cement Injector GB 171 N.

Device Operation

Preventing Unintentional Operation

Mechanism to prevent accidental activation of the reamer during use.

Pre-Use Functionality Test

Maintenance and Handling

Disinfection and Cleaning Procedures

Guidelines for manual cleaning and disinfection of the ACCULAN reamer.

Care and Damage Inspection

Instructions for routine care and inspection of the device for any damage.

Sterilization Methods and Parameters

Details on the validated steam sterilization procedures and parameters for the reamer.

Scheduled Maintenance

Battery GA 626 Usage Instructions

Protecting Battery from Moisture

Precautions to protect the battery and system from moisture.

Troubleshooting Guide

Technical Support Information

Device Specifications

Compatible Accessories

Product Disposal Guidelines

Braun Aesculap Acculan Specifications

General IconGeneral
CategoryMedical Equipment
Power SourceBattery
SterilizationAutoclavable
ManufacturerBraun Aesculap
MaterialStainless Steel
UsageSurgical