Aesculap®
Aesculap Endoscopic Technology
Instructions for use/Technical description
Full HD CMOS Camera System
Gebrauchsanweisung/Technische Beschreibung
Full HD CMOS Kamerasystem
Mode d’emploi/Description technique
Système de caméra Full HD CMOS
Instrucciones de manejo/Descripción técnica
Sistema de cámara CMOS Full HD
Istruzioni per l’uso/Descrizione tecnica
Sistema videocamera Full HD CMOS
Instruções de utilização/Descrição técnica
Sistema de Câmara Full HD CMOS
Gebruiksaanwijzing/Technische beschrijving
Full HD CMOS-camera systeem
Bruksanvisning/Teknisk beskrivning
Full HD CMOS kamerasystem
Инструкция по примению/Техническое описание
Камера Full HD CMOS
Návod k použití/Technický popis
Systém kamery CMOS full HD
Instrukcja użytkowania/Opis techniczny
System kamery Full HD CMOS
Návod na použivanie/Technický opis
Kamerový systém Full HD CMOS
Kullanım Kılavuzu/Teknik açiklama
Full HD CMOS kamera sistemi

Table of Contents

Other manuals for Braun Aesculap

Questions and Answers

  • J
    Jeremy MeyersAug 16, 2025
    How to fix a Braun Commercial Food Equipment clipping machine that won't start?
    • K
      Keith WestAug 16, 2025
      If your Braun Commercial Food Equipment clipping machine isn't starting, there might be a few reasons: * The Li-ion battery might not be loaded. Make sure to load the Li-ion battery. * The Li-ion battery might not be inserted. Ensure that the Li-ion battery is properly inserted. * The Li-ion battery could be defective. Try inserting a new Li-ion battery.
  • B
    Brandy PowellAug 19, 2025
    What to do if my Braun Commercial Food Equipment clipping machine pauses during operation?
    • B
      Brian PruittAug 19, 2025
      If your Braun Commercial Food Equipment clipping machine pauses during operation, here are a couple of potential causes: * The Li-ion battery may have been deactivated by its protective circuit. Try switching the clipping machine off and then on again. * The Li-ion battery might be empty. Try inserting a new Li-ion battery.
  • D
    Dennis TranAug 22, 2025
    What does it mean when the warning indicator lights up continuously on my Braun Commercial Food Equipment?
    • Y
      ycopelandAug 22, 2025
      If the warning indicator e lights up continuously on your Braun Commercial Food Equipment after inserting the Li-Ion battery, it means that too high a temperature (>50°) is measured in the Li-Ion battery during the charging process. Remove the Li-ion battery from the charging bay, let it cool down, and then try the charging process again. If the problem occurs again, have the Li-Ion battery inspected by the manufacturer, see Technical Service.
  • R
    Richard RobertsonAug 25, 2025
    Why is the warning indicator blinking on my Braun Commercial Food Equipment?
    • M
      Maria NelsonAug 26, 2025
      If the warning indicator 'e' is blinking on your Braun Commercial Food Equipment when the Li-Ion battery is inserted, it indicates a battery charging error, a foreign object on the contact system, or a defective Li-Ion battery. Remove the Li-Ion battery from the charging bay, clean the contact system, and then try the charging process again. If the problem persists, have the Li-Ion battery inspected by the manufacturer, see Technical Service.
  • V
    victorcampbellAug 28, 2025
    How to fix no image on the monitor of Braun Aesculap Medical Equipment?
    • D
      Douglas GarrisonAug 28, 2025
      If there is no image on the monitor of your Braun Medical Equipment, first, ensure that all units are connected to mains power and switched on. Check the fuse in the camera and replace it if it's broken. Inspect the video cable, connect it if it is not connected, and replace it if it is defective.
  • H
    Holly MoranAug 30, 2025
    Why is the image too dark on my Braun Aesculap Medical Equipment?
    • C
      charrisonAug 31, 2025
      If the image on your Braun Medical Equipment is too dark, check the following: Ensure the camera head is connected to the camera control unit and the camera plug is dry. If you are using a light guide cable, try connecting a new one. Also, check if the light source is dimmed down and increase the light source intensity. Check if the camera brightness is regulated down and regulate camera brightness up. If the image is still dark even without the camera, use a different endoscope and have the defective endoscope repaired by the manufacturer.
  • D
    Daniel Zamora IIISep 3, 2025
    What to do if there is unrealistic color representation on the monitor of Braun Medical Equipment?
    • B
      Barry WilsonSep 3, 2025
      If you are experiencing unrealistic color representation on the monitor of your Braun Medical Equipment, the issue might be caused by a white balance failure, so start white balance-adjustment. Another potential cause is a misadjusted monitor color setting, so reset to the factory setting. Finally, a defective video cable can cause this problem, so replace the video cable.
  • A
    Austin TaylorSep 6, 2025
    How to fix a fuzzy image on Braun Medical Equipment?
    • A
      Ashley WyattSep 6, 2025
      If the image on your Braun Medical Equipment appears fuzzy or poorly defined, it might be due to the object being out of focus. Turn the focusing ring on the endoscopic lens and adjust the focus until the image is sharp. Also, check for debris on the endoscope tip and clean it with a sterile cloth and isopropyl alcohol (70 %). Finally, if there is moisture on the camera cable plug, dry the plug with gauze before plugging it in at the camera socket.
  • S
    Sean RobertsonSep 9, 2025
    Why is there a color bar diagram on the monitor of my Braun Aesculap?
    • C
      Chad FisherSep 9, 2025
      If you see a color bar diagram on the monitor of your Braun Medical Equipment, it indicates that the camera cable is not connected to the camera control unit. Connect the camera cable to the camera control unit.
  • O
    ohubbardSep 12, 2025
    What to do if “System error” appears on the monitor OSD of Braun Medical Equipment?
    • J
      Jeffrey MasonSep 12, 2025
      If “System error” appears on the monitor OSD of your Braun Medical Equipment, the first step is to restart the camera, as this may be due to an internal product error.

Summary

Applicable to

Safe handling

Product description

Scope of supply

Lists the components included in the camera system package.

Components required for operation

Details additional equipment needed for endoscopic interventions.

Intended use

Describes the system's purpose in medical endoscopy visualization.

Operating principle

Explains how the camera system captures and processes endoscopic images.

Preparation and setup

Preparation

Outlines essential steps and precautions before operating the device.

Working with the camera control unit Full HD PV470 and the camera head PV471;PV472;PV473

System set-up

Instructions for connecting and configuring the camera system components.

Function checks

Procedures to verify the proper operation of the camera control unit and head.

Safe operation

Guidelines for the safe and effective use of the camera system.

Pendulum function (only PV471)

Describes the self-aligning feature and locking mechanism of the PV471 camera head.

Performing white-balancing

Explains the process of calibrating colors for realistic image rendition.

Buttons on the camera head

Details programmable buttons on the camera head and their functions.

Default setting

Shows default assignments for buttons on the camera head.

Validated reprocessing procedure

General safety instructions

Adherence to regulations and standards for sterile processing.

Single-use products

Information on products intended for one-time use and warnings against reprocessing.

General information

Guidelines on cleaning agents, material compatibility, and potential damage.

Cleaning;disinfection

Safety instructions and validated procedures for cleaning and disinfection.

Wipe disinfection for electrical devices without sterilization

Specific procedure for wiping electrical devices without sterilization.

Manual cleaning;disinfecting

Detailed steps for manual cleaning and immersion disinfection.

Sterilization

Instructions and warnings regarding sterilization methods for camera components.

Inspection, maintenance and checks

Procedures for inspecting and maintaining the product after cleaning cycles.

Packaging

Guidelines for packaging the product for storage or sterilization.

Storage

Recommendations for storing sterile and single-use products.

Maintenance

Troubleshooting list

Fuse replacement

Step-by-step guide for replacing fuses in the device.

Technical Service

Accessories;Spare parts

Technical data

Ambient conditions

Specifies the environmental conditions for operation, storage, and transport.

Disposal

Distributor in the US;Contact in Canada for product information and complaints

Braun Aesculap Specifications

General IconGeneral
CategoryMedical Equipment
ManufacturerBraun
MaterialStainless Steel
SterilizationAutoclavable
UsageSurgical Instruments

Related product manuals