Wake On LAN Power Requirements
Nominal power:
BCM957810A1006G: 3.0W
BCM957810a1008G: 4.5W
The tables below show the Wake On LAN power requirements for 1G adapters.
Table 16: BCM5708C Wake On LAN Power Requirements (Nominal Conditions)
100 Mbit Link 10 Mbit Link
NIC 3.3V Current (mA) NIC Power (W) NIC 3.3V Current (mA) NIC Power (W)
236
0.78 150 0.5
Table 17: BCM5709C and BCM5716 Wake On LAN Power Requirements (Nominal
Conditions)
100 Mbit Link 10 Mbit Link
NIC 3.3V Current (mA) NIC Power (W) NIC 3.3V Current (mA) NIC Power (W)
0
0.87 0 0.85
Environmental Specifications
Table 18: BCM5708 Environmental Specifications
Condition Operating Specification Storage Specification
Temperature 0°C to 55°C (+32°F to +131°F) –40°C to +85°C (–40°F to +185°F)
Relative humidity
5% to 85% (noncondensing)
40°C, 16 hour dwells at extremes
5% to 95% (noncondensing)
10°C/hour
Altitude Up to 10,000 ft. Up to 35,000 ft.
Shock 10g, 1/2 sine wave, 11 ms 60g, 1/2 sine wave, 11 ms
Vibration, peak to peak displacement 0.005 in. max (5 Hz to 32 Hz) 0.1 in. max (5 Hz to 17 Hz)
Vibration, peak acceleration
0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)
0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)
Table 19: BCM5709 and BCM5716 Environmental Specifications
Parameter Condition
Operating Temperature 0°C to 55°C
Air Flow Requirement (LFM) 0
Storage Temperature –40°C to +65°C
Storage Humidity 5% to 95% condensing
Vibration and Shock IEC 68, FCC Part 68.302, NSTA, 1A
Electrostatic/Electromagnetic Susceptibility EN 61000-4-2, EN 55024
Table 20: BCM957810A1006G Environmental Specifications
Parameter Condition
Operating Temperature 0°C to 55°C
Air Flow Requirement (LFM) 100
Storage Temperature –40°C to +65°C
Storage Humidity 5% to 95% condensing
Vibration and Shock IEC 68, FCC Part 68.302, NSTA, 1A
Electrostatic/Electromagnetic Susceptibility IEC 801-2, 3, 4, 5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom NetXtreme II SERIES and is the answer not in the manual?

Broadcom NetXtreme II SERIES Specifications

General IconGeneral
BrandBroadcom
ModelNetXtreme II SERIES
CategoryNetwork Card
LanguageEnglish

Related product manuals