HE-800A
5. OPERATION
36
-
. Parameter table
The parameter values can be stored independently for each program.
The allowable setting range for some parameters may vary from the range specified, depending on the settings of
other parameters. (Refer to “5-5-4. Main restrictions when setting parameters”.)
• Depending on the needle zigzag amount and feed amount settings, it may not be possible to carry out sewing at
some setting speeds.
The zigzag width ratio cannot be set when the rear tack pattern is set to an eyelet pattern.
If all underlays have been set, the order of sewing is underlays sewn together, then saw-shape underlays and then
rectangle underlays.
• Parameters that are not applicable to a particular program will be skipped and not displayed.
No. Setting items Setting range Unit Default
00 Sewing speed (zigzag part) 1,000 - 4,000 sti/min 100
<Other than Chinese
specifications>
3,600
<Chinese specifications>
3,200
Buttonhole stitch/Straight tack stitch 01
0: 1: 2: 3: 4:
0: Buttonhole (free)
1: Buttonhole (rectangle)
2: Buttonhole (radial)
3: Buttonhole (round)
4: Bar tack
1 1
02 Length of knife
4.0 - 32.0mm
However, when panel DIP
switch B – No. 3, No. 4 and
No. 5 are at OFF, OFF and
ON respectively when
initialization is carried out, the
initial value will be set to 6.0.
0.1 13.0
㧔6.0㧕
04 Zigzag pitch
0.10 - 2.00mm 0.025 0.350
05 Zigzag width
1.0 - 3.0mm 0.1 1.5
06 Knife X space
-0.4 - 1.0mm 0.1 0.4
07 Knife Y space
0.00 - 2.00mm 0.05 1.00