PG.
MENU 59 BOOTLOADER ENABLE FOR FIRMWARE UPDATING
CFF DCFF1 CFV
This Menu allows you to update the microcontroller firmware: to make it you must have a dedicate software.
For further information contact Brovind Elettronica company.
MENU 60 BOARD SOFTWARE VERSIONS
CFF DCFF CFV
This Menu displays some of the inspection parameters. To display these parameters, you must enter the
Menu and scroll down while pressing the “PR” key.
The parameters in order of appearance are:
1) Board code
2) Serial number
3) Number of inspections
4) Software version
5) Hardware constant of board
6) Voltage constant
7) Current constant
8) Max. current supplied by board
9) Temperature constant
MENU 61 DISPLAY SOFTWARE VERSIONS
CFF DCFF CFV
This Menu displays the software version of the display board.
MENU 70 “FULL” PASSWORD FOR CHANGING PARAMETERS - PASSWORD 1
CFF DCFF CFV
In menu 70 you can type in a password to protect the system from changes in the controller configuration
that the user does not want. To enter this security code go to menu 70. When cod. appears type in a
number from 1 to 99 and press PRG to save.
The password will be requested every time you press the PRG key for entry inside a menù
If you want to disable the password go back to Menu 70 select the active code, the display shows the
message (were HH is the actual psw) and after insert the code = 00.
Passwords 1 and 2 are mutually exclusive.
ATTENTION: Store the code in a safe place in case it is needed at a later date.
MENU 71 “PARTIAL” PASSWORD FOR CHANGING PARAMETERS - PASSWORD 2
CFF DCFF CFV
In menu 71 you can type in a password to protect the system from changes in the controller configuration
that the user does not want. This partial password allows the user to vary the speed of the vibrator in Menu
2, without requiring any type of code. To enter this security code go to menu 71. When cod. appears
type in a number from 1 to 99 and press PRG to save.
If you want to disable the password go back to Menu 71, select the active code, the display shows the
message (were HH is the actual psw) and after insert the code = 00.
Passwords 1 and 2 are mutually exclusive,
ATTENTION: Store the code in a safe place in case it is needed at a later date.
MENU 81 OPEN \ CLOSED LOOP
CFF DCFF CFV
Closed loop. Put 1 on Menu 81 - “A0” control parameter