10- 18 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Error codes
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
Code C90 (Option)
Description Extra I/0 (0) CAN communication error
Possible error
cause
Data from extra I/0 box /(0) not being received by
[A2]/ Check the CAN-bus cable and the
connections.
[A2] Restart the truck.
Code C91 (Option)
Description Extra I/0 (1) CAN communication error
Possible error
cause
Data from extra I/0 box /(1) not being received by
[A2]/ Check the CAN-bus cable and the
connections.
[A2] Restart the truck.
Code C92 (Option)
Description Configuration error Extra I/0 (0)
Possible error
cause
Incorrect setting of options in the extra I/0 box (0)
Check the outputs’ allocation on the I/0 expansion
box (0)
Code C93 (Option)
Description Configuration error Extra I/0 (1)
Possible error
cause
Incorrect setting of options in the extra I/0 box (1)
Check the outputs’ allocation on the I/0 expansion
box (1)
Code E101
Description Travel regulator does not correspond with the type
of truck
Possible error
cause
Incorrect travel regulator or electronic card has
been installed. The truck has a built-in control
function that checks to ensure the wrong combina
-
tion of travel regulator and electronic card has not
been installed.
Action Check travel regulator and electronic card.