EasyManua.ls Logo

BT LWE180 - Hydraulic System and Lift Cylinder Maintenance

BT LWE180
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preventive maintenance – P2 LPE 240
Maintenance schedule
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 5- 3
5000. Electrical functions
5000.1 Check the operation of the brake microswitch
in the upper and lower brake positions. Lubri
-
cate the switch head
I I/L
5000.2 Check the function of the safety switch
against collision
I
5000.3 Check the operation of the gate switch I I
5000.4 Check the operation of the platform switch I I
5000.5 Check the horn I I
5000.6 Check for wear to the cables I
5000.7 Check the operation of the driver's controls I I
5000.8 Check the error code log and operatingtimes I I
5110. Battery
5110.1 Check electrolyte levels, 10-15 mm above
the cell plates
M
5110.2 Check connections on the battery,
truck and charger
I
5110.3 Check that the cell and pole guards are
undamaged
I
5110.4 Check the fluid density and temperature M
5110.5
Remove overflow fluid from the battery trough
C
5110.6 Check the battery lock I
5400 Power system
5400.1 Clean and check the mountings
C/T
1
C/T
5400.2 Tighten the cable connections
T
1
5400.3 Check the contactor points on K10 and K30 I
5400.4 Check the contactor movement I
I: Inspect, correct and replace if necessary. T: Tighten C: Clean L: Lubricate
M: Measure, correct if necessary
Pos.
no.
Work to carry out
Interval in hours - may vary due to ap-
plication
5 20 80 500 1000 3000
Interval in days/weeks/months - may
vary due to application
1d 1w 1m 6m 12m 36m

Table of Contents

Related product manuals