Preventive maintenance – P2 LPE 240
Maintenance schedule
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497 
© BT Europe AB Service Guide  LWE180, LWE200, LPE200, LPE240 5-  3
5000. Electrical functions
5000.1 Check the operation of the brake microswitch 
in the upper and lower brake positions. Lubri
-
cate the switch head
I I/L
5000.2 Check the function of the safety switch 
against collision
I
5000.3 Check the operation of the gate switch I I
5000.4 Check the operation of the platform switch I I
5000.5 Check the horn I I
5000.6 Check for wear to the cables I
5000.7 Check the operation of the driver's controls I I
5000.8 Check the error code log and operatingtimes I I
5110. Battery
5110.1 Check electrolyte levels, 10-15 mm above 
the cell plates
M
5110.2 Check connections on the battery, 
truck and charger
I
5110.3  Check that the cell and pole guards are 
undamaged
I
5110.4 Check the fluid density and temperature M
5110.5
Remove overflow fluid from the battery trough
C
5110.6 Check the battery lock I
5400 Power system
5400.1 Clean and check the mountings
C/T
1
C/T
5400.2 Tighten the cable connections
T
1
5400.3 Check the contactor points on K10 and K30 I
5400.4 Check the contactor movement  I
I: Inspect, correct and replace if necessary. T: Tighten C: Clean L: Lubricate 
M: Measure, correct if necessary
Pos. 
no.
Work to carry out
Interval in hours - may vary due to ap-
plication
5 20 80 500 1000 3000
Interval in days/weeks/months - may 
vary due to application
1d 1w 1m 6m 12m 36m