12 S5 Battery Validation System
Plugs and Connectors
Qty Part Name Picture Purpose
qty VSL
pigtails
1/4” male quick disconnect ring
terminal / tabs
To attach VSL pigtail quick
disconnects to battery terminals
1 per
VM-24
16-pin WAGO plug (shown with
terminating tool)
Plugs VSL wires into VM-24
module
1 per
VM-24
10-pin WAGO plug
Plugs VSL wires into VM-24
module
1 per
VM-24
8-pin screw terminal
Plugs battery thermistors into
VM-24 module
1 per
SCM-600
2-pin screw terminal
Plugs ambient thermistor into
SCM-600
1 per
SCM-600,
2 per
VM24,
2 per
CM-2
4-pin WAGO plug
Attaches communication wires
into VM-24 and CM-2 modules
1 per
SCM-600,
2 per
VM24,
2 per
CM-2
2-pin WAGO plug
Attaches power wires into
VM-24 and CM-2 modules
1 per CT
or shunt
5-pin screw terminal
Attaches current transducer
(CT) wires into CM-2 module
SCM-600,
2 for 1-2
string;
4 for 3-4
string
4-pin screw terminal
Attaches load current lead
(LCL) cables into SCM-600
controller module
2 per
SCM-600
4-position screw terminal (pair)
Attaches auxiliary inputs into
the SCM-600
2 per
SCM-600
9-position screw terminal (pair)
Attaches auxiliary outputs out
of the SCM-600
2 per
SCM-600
Communications Termination Plug
Attaches to SCM-600 Comm
plug and last module’s OUT
Comm plug