iValve Lift Control Valve6 Installation and commissioning
24/31
300-I-9010544-EN-01/10.2014
6. Disconnect the 24 V supply from the input “Monitoring Emergency
stop DOWN function” on the lift control
7. Short circuit the input “UCM/A3-valve” on the lift control
8. Execute a travel in any direction
I This travel shall complete normally until the selected stop is reached.
Afterwards the lift control shall indicate an SMA-error.
9. Issue the command for another travel
I The lift must refuse to execute further travels until the SMA-error is reset
on the lift control.
Test of the UCM/A3-valve
Compliance with the permissible stop distances and decelerations under
all imaginable operating conditions is confirmed by the type examination
of the iValve and NOT subject to this test.
Compliance with the permissible stop distances and decelerations under
all imaginable operating conditions is confirmed by the type examination
of the iValve and NOT subject to this test. In the course of the accep
tance test the installer must prove the proper placement of the shaft
switches at
dmax=250mm–vmax•t
below the floor. (see Planung Information 300-D-9010542).
Then evidence of the basic function of the UCM/A3-valve
and stopping within 1000 mm below the floor must be provided by a test
to be specified by the lift control manufacturer. The test can be executed
e.g. at inspection speed.
Reference: 300-I-9010544-EN-01