iValve Lift Control Valve 6 Installation and commissioning
21/31
300-I-9010544-EN-01/10.2014
When the serial no.s on the iValve, on the Quality-Certificate and on the
ParamCard match:
5. Insert ParamCard (C) on the iCon (D) and snap it into place
6. File the Quality-Certificate in the lift register/file
7. Make sure that the lift power unit is ready for operation
8. Energise the iCon
9. Check after approx. 10s that every single LED on the iCon either
lights up or is off, there must be no flashing LED
When one or more LEDs flash:
10. Inquire the meaning of the flashing LED(s)
6.2.4 Hydraulic fluids and oil additives
Hydraulic characteristics
Surroundings
Description, value, unit
Requirement
Oil temperature HL and HLP mineral oils to DIN 51 524, other
fluids – contact BUCHER!
Oil additive: Shell Tonna S.
When the movement of the lift cylinder at low speeds tends to be jerky,
an oil additive with special sliding properties is required. In this case, the
oil additive Shell Tonna S is approved.
Alternatively: standard HLP hydraulic oil Motorex Hydrogliss 202.
When Shell Tonna S cannot be employed, an alternative is to use a
standard HLP hydraulic oil together with the oil additive supplied by
Bucher Hydraulics AG.
Other oil additives are not permitted.
ATTENTION!
The volume of oil additive that is mixed in must not exceed 2% of
the existing total oil volume.
Bucher Hydraulics cannot guarantee the proper functioning of the lift
control valve if other additives are used or if the maximum permissible
amount of the above additives is exceeded.