3
|
Product
description
Büchi
Labortechnik
AG
14
/
102
Operation
Manual
Pure
Chromatography
Instruments
3.2
Configuration
3.2.1
Front
view
Pure
C-810
/
C-815
5
1
0
9
8
1
2
3
4
6
7
Fig.2:
Front
view
Pure
C-810
/
C-815
1
Control
panel
2
RFID
reader
3
On/Off
switch
4
USB
Port
5
Injection
port
6
Cartridge
holder
7
Flash
pump
8
ELSD
flow
split
valve
(C-815
only)
9
ELSD
nebulizer
(C-815
only)
10
Fraction
collection
bay
All manuals and user guides at all-guides.com
13
15
Table of Contents
Main Page
Table of Contents
3
About this Document
8
Warning Notices in this Document
8
Symbols
8
Warning Symbols
8
Mark-Ups and Symbols
8
Trademarks
9
Connected Devices
9
Safety
10
Proper Use
10
Use Other than Intended
10
Staff Qualification
10
Location of Warning Signs on the Product
11
Residual Risks
11
Faults During Operation
11
Malware Infection Due to Connections with Other Devices or Network
11
Damage to the Internal Memory Due to Incorrect Shutting down of the Instrument
12
Personal Protective Equipment
12
Modifications
12
Product Description
13
Description of Function
13
Configuration
14
Front View Pure C-830 / C-835 / C-850
15
Rear View
15
Connections on Gradient Valve
17
Type Plate
17
Scope of Delivery
18
Technical Data
18
Pure Chromatography Instruments
18
Ambient Conditions
20
Material
21
Transport and Storage
22
Transport
22
Storage
22
Lifting the Instrument
23
Installation
24
Before Installation
24
Installation Site
24
Securing against Earthquakes
24
Establishing Electrical Connections
25
Establishing Solvent Connection
25
Installing the Solvent Level Sensor
26
Assigning Solvent to Solvent Lines
26
Calibrating the Solvent Level Sensor
27
Installing the Exhaust (ELSD Only)
28
Assembling the Waste Bottle
28
Installing the Waste Level Sensor
28
Calibrating the Waste Level Sensor
29
Assembling the Dry Air Supply (Option)
29
Assembling the Gas Connection (Option)
30
Assembling the Solvent Bottle Platform (Option)
31
Assembling the Sample Loop (Prep Instruments Only)
32
Operation
33
Control Panel
33
Layout of Control Panel
33
Enter Value
34
Menu Bar
35
Conditions Panel
37
Collection Panel
38
Gradient Panel
39
Run Panel
40
Solvent Selection Panel
41
Detector Selection Panel
41
6.1.10 Slope Detection Panel
42
Editing a Method
42
Selecting a Cartridge (Flash Mode)
42
Selecting a Column (Prep Mode)
44
Selecting a Solvent
45
Editing the Gradient
45
Editing Detector Selection
48
Editing the Wavelength for the UV Detector
48
Editing the Fraction Collection Criteria
49
Editing the Fraction Collection Time
50
Editing the Vapor Sensor Sensitivity
52
6.2.10 Saving a Method
52
Editing a Solvent
53
Adding a New Solvent
53
Deleting a Solvent
54
Tasks During a Separation
54
Introducing a Sample into the Prep System
54
Injecting a Sample into the Flash System
55
Installing and Removing a Cartridge
57
Installing and Removing a Column
58
Inserting the Fraction Collection Tray
60
Selecting an Existing Method
61
Selecting Values on the Dialog Box Sample Loading
61
Performing a Flash Separation Using a Method
61
Preparing the Instrument
61
Selecting the Flash Mode (Pure C-850 Only)
62
Starting Flash Separation Using a Method
62
Changings During a Separation
62
Ending a Flash Separation
63
Shutting down the Instrument
63
Performing a Flash Separation Manually
63
Preparing the Instrument
63
Selecting the Flash Mode (Pure C-850 Only)
64
Starting Flash Separation Manually
64
Changings During a Separation
65
Ending a Flash Separation
65
Shutting down the Instrument
65
Performing a Prep Separation Using a Method
66
Preparing the Instrument
66
Selecting the Prep Mode (Pure C-850 Only)
68
Related product manuals
Buchi Pure C-810
102 pages
Buchi Pure C-850
102 pages
Buchi ProxiMate
94 pages
Buchi B-811
54 pages
Buchi R-210
80 pages
Buchi K-424
22 pages
Buchi N-500 NIRFlex
96 pages
Buchi KjelFlex K-360
72 pages
Buchi Rotavapor R-200
60 pages
Buchi Rotavapor R-3000
32 pages
Buchi KjelMaster K-375
162 pages
Rotavapor R-220 Pro Continuous
90 pages