Servicing 5
Wall-mounted condensing gas boiler Buderus 800 - Subject to modifications resulting from technical improvements!
45
Code Meaning
7A Voltage in burner-control unit too low (lower than 187 V~) or too high (higher than 246 V~)
Possible
cause
Action
1 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator
Code Meaning
7C Mains supply interrupted
Possible
cause
Action
1 A problem with the mains supply Check the mains supply during operation (230V~)
2 Reset button pressed too briefly Press the Reset button until "r" appears in the display
Code Meaning
7F F3 fuse defect, or burner control unit error
Possible
cause
Action
1 Short circuit in the 24V circuit (three-way-valve or
connector)
Check for a short circuit and replace the F3 fuse
(see subsection 5.3.3)
2 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator
Code Meaning
7H Voltage peaks in the UBA
Possible
cause
Action
1 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator
Code Meaning
7L Internal UBA error
Possible
cause
Action
1 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator