Servicing 5
Wall-mounted condensing gas boiler Buderus 800 - Subject to modifications resulting from technical improvements!
47
Code Meaning
E with
any
character
but P
UBA defective
Possible
cause
Action
1 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator
2 UBA may be defective Press reset. If fault code remains then try to temporarily
connect a different UBA (see subsection 5.3.5)
Code Meaning
EP Non compatible UBA fitted
Possible
cause
Action
1 Regulating device may have to cope with interference Check if for example induction fields interfere with the
regulating device
Check if the are any peaks in the electrical network
caused by maybe windmills or a power generator
2 Kim connected incorrectly or KIM defective Check the KIM connector and fan connector (see
subsection 5.3.21).
If the connectors are fine then contact Buderus
Problem: No DHW , despite the system being operational
Set chimney sweep switch to "0"
Check three-way valve replace if necessary
Check DHW sensor and replace if necessary
Problem: No heating, despite that there is a demand for heat and the boiler is operational
Check regulating device configuration and/or the wiring
Check the wiring between the regulating device and the UBA (see subsection 5.3.18)
Check all the wiring
Check the UBA and replace if necessary (see subsection 5.3.5)