Bunn-O-Matic Corporation
17
Setup and Programming
Programming Lockout
If the programming cannot be access then the programming lockout
switch is in the Lock position. The switch is located on the control
board. Remove the top panel, locate the switch and place it into the
Unlock position.
Level 1 Programming
Press the hidden switch for one second to access.
This function allows the operator to prevent or allow brewing if the water temperature is
less than the Set Ready temperature.
Level 2 Programming
Press and hold the hidden switch for 5 seconds
This function allows the operator to select the language used for the display.
This function allows the operator to select if numeric settings are displayed in English or
Metric units.
This function allows the operator to view the brew settings for various coffee recipes
stored into the brewer. It also allows the operator to modify any of the brew settings for a
particular recipe stored in the brewer.
This function allows the operator to assign a recipe to (or disable) each of the 3 brew
switches (A, B, C). Any saved recipes listed under “Review Recipes” can be assigned to
a brew switch. Only one recipe per brew switch is allowed.
This function allows the operator to set Brew Volumes, Bypass %, Pulse Brew/Preinfu-
sion Times and Drip Out Times for each coffee name stored in the grinder’s memory.
This function allows the operator to adjust the brew water temperature in the tank. This
also sets the hot water faucet dispense temperature. (Range 150-207°F)
This function allows the operator to set the minimum temperature allowable to start a
brew cycle. The range can be from 2° to 20° F below the set temperature. The water
must be at the Ready temperature or higher for the display to indicate Ready To Brew. If
brew lockout is enabled, the brewing process won’t start below this Ready temperature.
MEMORY
LOCK UNLOCK
PROGRAMMING
LOCKOUT SWITCH
P3048
UNITS
Metric ENG
DONE
REVIEW RECIPES ?
NO YES
ASSIGN RECIPE ?
NO YES
SET NEW RECIPE ?
NO YES
MASTER TEMP 200
O
(-) (+)DONE
Set Language?
NO YES
READY DEGREE 5
O
(-) (+)DONE
BREW LOCKOUT ?
ON OFFDONE