11
7 DEACTIVATION
7.1 Safety instructions
DANGER!
High pressure danger.
Switch o the pressure before working on the device or system.
Vent or empty the lines.
Danger from electrical voltage.
Before working on the device or system, switch o the power
supply. Secure it against reactivation.
Observe the applicable accident prevention and safety regula-
tions for electrical devices.
WARNING!
Risk of injury due to improper disassembly.
Disassembly work may be carried out by authorised techni-
cians only, with the appropriate tools.
7.2 Disassembly
Switch o pressure and drain lines.
Switch o electrical voltage.
Remove the cable plug.
Valve with threaded connection:
Hold the valve on the valve body using an open-end wrench
and unscrew from the pipeline.
Valve with ange connection:
Loosen nut and remove coil.
Remove the valve body from the manifold.