EasyManua.ls Logo

Burkert 8045 - Technical Data

Burkert 8045
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Technical data
Type 8045
1. Measured value and type of the device
2. Specification of the flow sensor
3. Specification of the DO1 digital output
4. Specifications of the relay outputs DO2 and DO3
5. Electrical power supply and current consumption
6. Manufacturing code
7. Conformity marking
8. Warning: before using the device, take into account the tech-
nical specifications described in the Operating Instructions.
9. Certification
10. Fluid temperature range and fluid nominal pressure
11. Protection class of the device
12. Specification of the DI1 digital input
13. Serial number
14. Order code
15. Shows the flow direction
Fig. 1 : Rating plate of the 8045 insertion electromagnetic
flowmeter (example)
6. TECHNICAL DATA
6.1. Conditions of use
Ambient temperature
–10...+60 °C
Air humidity
< 85 %, non condensated
Height above see level
max. 2000 m
Operating conditions
Continuous
Equipment mobility
Fixed
Use
Indoor and outdoor
(Protect the device against electromag-
netic interference, ultraviolet rays and,
when installed outdoors, against the
effects of climatic conditions)
Installation category
Category I according to UL/
EN 61010-1
Degree of pollution
Degree 2 according to UL/
EN 61010-1
Protection class
according to
IEC / EN 60529
IP65
1)
, if the device is wired and if the
cable glands are tightened and the
cover lid is screwed tight.
1)
not evaluated by UL