• Product used on a piping (PS = maximum admissible pressure;
DN = nominal diameter of the pipe)
Type of fluid Conditions
Fluid group 1, Article 4, Paragraph 1.c.i DN≤25
Fluid group 2, Article 4, Paragraph 1.c.i
DN≤32
or PSxDN≤1000
Fluid group 1, Article 4, Paragraph 1.c.ii
DN≤25
or PSxDN≤2000
Fluid group 2, Article 4, Paragraph 1.c.ii
DN≤200
or PS≤10
or PSxDN≤5000
• Product used on a vessel (PS = maximum admissible pressure)
Type of fluid Conditions
Fluid group 1, Article 4, Paragraph 1.a.i PS ≤ 200 bar
Fluid group 2, Article 4, Paragraph 1.a.i PS ≤ 1000 bar
Fluid group 1, Article 4, Paragraph 1.a.ii PS ≤ 500 bar
Fluid group 2, Article 4, Paragraph 1.a.ii PS ≤ 1000 bar
8
Technical data
Type 8221