7
Instructions on operation in the potentially explosive atmosphere
BVS 16 ATEX E 118 X
5 INSTRUCTIONS ON OPERATION
IN THE POTENTIALLY
EXPLOSIVE ATMOSPHERE
When using the device in an potentially explosive atmosphere,
observethefollowing:
5.1 Media in the potentially explosive
atmosphere
Ifexplosivemediaareused,thiscan resultinadditional
explosion risks.
5.2 Actuators/valves in the potentially
explosive atmosphere
Use in an explosive atmosphere may be restricted by the
actuators/valves.Observetheoperatinginstructionsofthe
actuators/valves.
5.3 Cleaning in the potentially
explosive atmosphere
DANGER!
Risk of explosion caused by electrostatic charge.
Cleanthedevicesurfacebygentlywipingitwithadampor
anti-static cloth only.
Check that cleaning agents are approved for use in
explosive atmospheres.
5.4 Adhesive labels for the potentially
explosive atmosphere
Type label
Additional adhesive
label
WARNING
1. DO NOT CONNECT OR
DISCONNECT WHEN ENERGIZED
2. DO NOT OPEN WHEN
ENERGIZED
3. POTENTIAL ELECTROSTATIC
CHARGING HAZARD -
see
instructions
Fig. 1: Arrangement of the adhesive labels for the potentially explosive
atmosphere, additional adhesive label