OPERATION MANUAL
The 159 is equipped with extensive protection circuits that protect it
and the connected speakers from damage in the event of a fault.
If an error occurs, this is indicated by the LED (1) on the front
of the 159. It flashes orange in the event of an error.
MORE DETAILS ABOUT THE ERROR WILL BE FOUND ON THE CONTROL PANEL.
BURSYNC  ERROR
BurSync
Status
Input Output Master Slave
Description:
The BurSync output on the last power amplifier was connected to the BurSync
input on the first power amplifier. This results in a ring connection.
Troubleshooting:
1. Switch off all power amplifiers.
2. Remove the BurSync cable connecting the last power amplifier to the first.
SHORT CIRCUIT ERROR OR TEMPORARY OVERLOAD
Sequence
Status
1 2 3 4 5 On
Description:
There is a short circuit in the cables, or the power
amplifier was temporarily overloaded.
Troubleshooting:
1. Switch off the power amplifier.
2. Check the cables between the power amplifier and the speakers.
3. Correct any faults in the cables.
4. Switch the power amplifier on again.
If the error is still displayed, contact your dealer.
Troubleshooting