11 | Troubleshooting
26 / 32 0870207738_RA_RC0400-0630C_USA_-_IM_en
The oil is emulsified. The vacuum pump sucked in
liquids or significant
amounts of vapour.
Flush the vacuum pump
(contact Busch).
Clean the filter of the gas
ballast valve (GB).
Modify the operational
mode (see Conveying
Condensable Vapours
[14]).
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.